Mean Well LRS Series Enclosed Rectifier 35W Single Output Switching Power Supply LRS-35-5 LRS-35-12 LRS-35-24 LRS series dari 35W- 350W
Teknis:
Model | LRS-35-5 | LRS-35-12 | LRS-35-15 | LRS-35-24 | LRS-35-36 | LRS-35-48 | |
Output |
Tegangan DC | 5V | 12V | 15V | 24V | 36V | 48V |
NOMINAL ACRENT | 7A | 3A | 2.4A | 1.5A | 1A | 0.8A | |
RANGE saat ini | 0 ~ 7A | 0 ~ 3A | 0 ~ 2.4A | 0 ~ 1.5A | 0 ~ 1A | 0 ~ 0,8A | |
Kekuatan nominal | 35W | 36W | 36W | 36W | 36W | 38.4W | |
RIPPLE & NOISE (maks.)Catatan.2 | 80mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | |
Tegangan ADJ. Jangkauan | 4.5 ~ 5.5V | 10.2 ~ 13.8V | 13.5 ~ 18V | 21.6 ~ 28.8V | 32.4 ~ 39.6V | 43.2 ~ 52.8V | |
TeganganToleransi Catatan.3 | ± 2,0% | ± 1,0% | ± 1,0% | ± 1,0% | ± 1,0% | ± 1,0% | |
Peraturan garisCatatan.4 | ± 0,5% | ± 0,5% | ± 0,5% | ± 0,5% | ± 0,5% | ± 0,5% | |
Peraturan bebanCatatan.5 | ± 1,0% | ± 0,5% | ± 0,5% | ± 0,5% | ± 0,5% | ± 0,5% | |
SETUP, RISE waktu | 1000ms, 30ms/230VAC 2000ms,30ms/115VAC pada beban penuh | ||||||
TANGGUNG WAKTU (Typ.) | 30ms/230VAC 12ms/115VAC pada beban penuh | ||||||
Input |
Rentang tegangan | 85 ~ 264VAC 120 ~ 373VDC | |||||
RANGKAH FREKWENSI | 47 ~ 63Hz | ||||||
Efisiensi (jenis) | 82% | 86% | 86% | 88% | 88% | 89% | |
AC CURRENT (Jenis) | 0.7A/115VAC 0,42A/230VAC | ||||||
INRUSH CURRENT (Jenis) | START Dingin 45A/230VAC | ||||||
Kebocoran arus | < 0,75mA / 240VAC | ||||||
Perlindungan |
Overload | 110 ~ 150% daya output nominal | |||||
Tipe perlindungan: modus cegukan, pulih secara otomatis setelah kondisi kesalahan dihapus | |||||||
Overvoltage | 5.75 ~ 6.9V | 13.8 ~ 16.2V | 18.75 ~ 21.75V | 28.8 ~ 33.6V | 41.4 ~ 48.6V | 55.2 ~ 64.8V | |
Tipe perlindungan: Matikan tegangan O/P, hidupkan kembali untuk pulih | |||||||
Lingkungan |
Waktu kerja. | -30 ~ +70°C (Lihat "Derating Curve") | |||||
Kelembaban Kerja | 20 ~ 90% RH tidak kondensasi | ||||||
Waktu Penyimpanan, Kelembaban | -40 ~ +85°C, 10 ~ 95% RH tidak kondensasi | ||||||
Koefisien waktu | ± 0,03%/°C (0 ~ 50°C) | ||||||
Getaran | 10 ~ 500Hz, 5G 10min./siklus, 60min. masing-masing di sepanjang sumbu X, Y, Z | ||||||
KATEGORI SURVOLTAGE | Ⅲ; Menurut BS EN/EN61558, BS EN/EN50178, BS EN/EN60664-1, BS EN/EN62477-1; ketinggian hingga 2000 meter | ||||||
Keamanan& EMC (Catatan 9) |
Standar Keselamatan |
UL62368-1, TUV BS EN/EN62368-1, BS EN/EN60335-1, BS EN/EN61558-1/-2-16, CCC GB4943.1, BSMI CNS14336-1, EAC TP TC 004,AS/NZS 60950.1 ((oleh CB),KC K60950-1 ((hanya untuk LRS-35-12/24),BIS IS13252 ((Part1)): 2010/IEC 60950-1: 2005 disetujui | |||||
Tegangan WITHSTAND | I/P-O/P:4KVAC I/P-FG:1.25KVAC | ||||||
Resistensi isolasi | I/P-O/P, I/P-FG, O/P-FG:100M Ohm / 500VDC / 25°C/ 70% RH | ||||||
EMC EMISI | Kesesuaian dengan BS EN/EN55032 (CISPR32) Kelas B, BS EN/EN55014, BS EN/EN61000-3-2,-3, GB/T 9254, BSMI CNS13438, EAC TP TC 020,KC KN32,KN35 ((hanya untuk LRS-35-12/24)) | ||||||
Imunitas EMC | Kesesuaian dengan BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61000-6-2 (BS EN/EN50082-2), tingkat industri berat, EAC TP TC 020,KC KN32,KN35 ((hanya untuk LRS-35-12/24)) | ||||||
TANYA |
MTBF | 3201.5K jam min. Telcordia SR-332 (Bellcore) ; 655.5Khrs min. MIL-HDBK-217F (25°C) | |||||
Dimensi | 99*82*30mm (L*W*H) | ||||||
Pengemasan | 0.23kg; 60pcs/14.8Kg/0.88CUFT |
Solusi
Solusi lengkap kami untuk perusahaan telekomunikasi di dalam dan di luar Cina menetapkan standar baru di industri.Rencana profesional kami inovatif dan berpikiran ke depan, membantu pelanggan tetap di depan kompetisi. dukungan teknis kami responsif dan dapat diandalkan, dengan tim insinyur yang dapat menangani masalah teknis yang kompleks.Layanan perawatan kami dirancang untuk mengoptimalkan kinerja sistem telekomunikasiDengan jaringan mitra terpercaya di seluruh dunia, kami dapat memberikan pengalaman layanan yang mulus bagi klien kami.
.
FAQ:
1T: Hei, saya ingin tahu, bagaimana Anda menjaga produk Anda berkualitas tinggi?Aku tidak tahu.
2T: Saya baru memulai, jadi bisakah saya memesan jumlah kecil?Aku tidak tahu.
3P: Saya ingin tahu lebih banyak tentang perusahaan Anda. Bisakah Anda memberi tahu saya?Aku tidak tahu.
4T: Apa yang membuat perusahaan Anda lebih baik dari yang lain?Aku tidak tahu.
5.Q: Saya ingin memeriksa produk Anda terlebih dahulu. Dapatkah saya mendapatkan sampel dan harga?Aku tidak tahu.